BLUGUARD SmartBus P900-V16N Bedienungsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 31
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
version 1.1
19
SmartBus P900
-
V16
N
NN
N
USER MANUAL
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. Zone indicator [1] and [2] will flash. Enter the partition number that you wish to arm
followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. The keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
8. Leave the premises only via the EXIT/ENTRY zone.
9. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
10. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
If your user code has access to 1 partition only
[*] + [USER CODE] + [#]
(Leave via ENTRY/EXIT Zone)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Press the [*] key to cancel any unintended entries.
3. Enter a valid 4-digit [USER CODE]. If you enter mistakes, press [*] key and re-enter the
code followed by [#] key to confirm your command.
4. The P1 indicator will illuminate if the entered user code is Partition 1 user code.
5. The P2 indicator will illuminate if the entered user code is Partition 2 user code.
6. The keypad audible indicator will sound on and off for the duration of the EXIT delay. Any
bypassed zones will be shown by the flashing zone indicators.
7. Leave the premises only via the EXIT/ENTRY zone.
8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[1] + [1 or 2] + [#]
(Press and hold down for 2 seconds)
1. Ensure that all zone indicators are distinguished; if not, check that all protected premises
are closed.
2. Enter and hold down key [1] for 2 seconds.
3. Zone indicator [1] and [2] will flash.
4. Enter key [1] to arm Partition 1 or enter key [2] to arm Partition 2 followed by [#] key.
5. The P1 indicator will illuminate of Partition 1 is armed.
6. The P2 indicator will illuminate of Partition 2 is armed.
7. Leave the premises only via the EXIT/ENTRY zone.
8. During AWAY arming, the telephone line will be supervised hourly. If the telephone line is
disconnected, a new trouble condition will be registered (please refer to View System
Trouble).
9. User will be given an ENTRY delay time to disarm the system when enter the protected
premises via ENTRY/EXIT zone.
[2] + [1 or 2] + [#]
(Press and hold down for 2 seconds)
PARTITION DAY ARMING
FASTKEY AWAY ARMING EITHER 1 PARTITION
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 30 31

Kommentare zu diesen Handbüchern

Keine Kommentare